Analyzing dioxins, including coplanar PCBs, is a complex process due to the presence of multiple isomers and their extremely low concentrations in environmental samples. To support accurate and reliable results, KANTO offers high-purity solvents and specialized sample cleanup agents that are carefully optimized not to interfere with the target compounds in dioxin analysis.
Our “Guaranteed by x10,000 Concentrated Solvent” series undergoes rigorous blank testing to ensure minimal contamination. These solvents are tested using GC/MS (SIM mode), confirming that levels of 4-8 chlorinated dibenzo-p-dioxins (PCDDs) and dibenzofurans (PCDFs) are maintained below 10 µg/L (10 ppb) in concentrated form. This translates to less than 1 ng/L (1 ppt) in the original product, ensuring extremely low background levels suitable for trace dioxin analysis.
These high-performance solvents are ideal for laboratories conducting high-sensitivity dioxin analysis in environmental monitoring, food safety testing, and regulatory compliance.
PRODUCT LIST
| PRODUCT CODE | ITEM | GRADE | PACKAGE |
|---|---|---|---|
| 01025-79 | Acetone | for dioxins analysis(x10,000) | 1L |
| 01025-76 | Acetone | for dioxins analysis(x10,000) | 3L |
| 11338-79 | Dichloromethane | for dioxins analysis(x10,000) | 1L |
| 11338-76 | Dichloromethane | for dioxins analysis(x10,000) | 3L |
| 14039-78 | Ethanol (99.5) | for dioxins analysis(x10,000) | 1L |
| 14039-76 | Ethanol (99.5) | for dioxins analysis(x10,000) | 3L |
| 18636-79 | Hexane | for dioxins analysis(x10,000) | 1L |
| 18636-76 | Hexane | for dioxins analysis(x10,000) | 3L |
| 25184-79 | Methanol | for dioxins analysis(x10,000) | 1L |
| 25184-76 | Methanol | for dioxins analysis(x10,000) | 3L |
| 40500-79 | Toluene | for dioxins analysis(x10,000) | 1L |
| 40500-76 | Toluene | for dioxins analysis(x10,000) | 3L |
Solvents for Analysis of Dioxins “Guaranteed by x100,000 Concentrated Solvent”
For the precise analysis of ultra-trace levels of dioxins in water, food, and biological samples, KANTO offers solvents with exceptionally low background contamination. These solvents, labeled as “Guaranteed by x100,000 Concentrated Solvent,” undergo stringent blank testing using High-Resolution Gas Chromatography/High-Resolution Mass Spectrometry (HRGC/HRMS). The results confirm that 4-8 chlorinated dibenzo-p-dioxins (PCDDs), dibenzofurans (PCDFs), and coplanar PCBs are consistently below the detection limit, ensuring maximum reliability and minimal interference during analysis.
Each product (1L × 6 bottles) is accompanied by an inspection report issued by the Chemicals Evaluation and Research Institute, Japan (CERI)—a trusted third-party organization responsible for conducting the blank test. This certification ensures the highest standard of quality assurance for dioxin analysis in critical applications such as environmental monitoring, food safety, and biological studies.
PRODUCT LIST
| PRODUCT CODE | ITEM | GRADE | PACKAGE |
|---|---|---|---|
| 01025-97 | Acetone | for dioxins analysis(x100,000) | 1L×6 |
| 11338-97 | Dichloromethane | for dioxins analysis(x100,000) | 1L×6 |
| 18636-97 | Hexane | for dioxins analysis(x100,000) | 1L×6 |
| 40500-97 | Toluene | for dioxins analysis(x100,000) | 1L×6 |
Sample Cleanup Solution for Dioxin Analysis
Kanto Chemical has developed a specialized chromatographic adsorbent—Active Carbon-Dispersed Silica Gel—specifically designed for the pretreatment process in dioxin analysis. This innovative product combines the adsorption capabilities of activated carbon and silica gel, offering a highly effective cleanup solution to improve the accuracy and reliability of dioxin and coplanar PCB measurements.
The Active Carbon-Dispersed Silica Gel provides several key advantages:
- Efficient separation of dioxins and coplanar PCBs.
- Minimal lot-to-lot variation, thanks to uniform particle size.
- Lower background contamination (blank values), achieved through a proprietary treatment process, eliminating the need for prior cleaning.
| PRODUCT CODE | ITEM | GRADE | PACKAGE |
|---|---|---|---|
| 01875-43 | Active carbon-dispersed silica gel | for dioxins analysis | 10 g |
| 01894-96 | Active carbon-dispersed silica gel reversible column | for dioxins analysis | 1pack(5 pieces/pack) |
With the rising demand for ultra-trace analysis in environmental, food, and water quality testing, the need for highly purified reagents and solvents has never been greater. At KANTO, we are committed to delivering top-tier analytical products by utilizing our own advanced distillation and purification equipment. Our reagents and solvents undergo strict quality control, including precise testing at 300 and 5,000 times concentration to ensure suitability for residual pesticide and PCB testing. We provide stable, high-quality products optimized for GC/MS and PCB conformity testing, meeting the stringent standards required for accurate ultra-trace analysis.
PRODUCT LIST
| PRODUCT CODE | ITEM | GRADE | PACKAGE |
|---|---|---|---|
| 01025-1B | Acetone | for pesticide residue & PCB analysis(x5,000) | 1L |
| 01025-2B | Acetone | for pesticide residue & PCB analysis(x5,000) | 3L |
| 12-3B | Acetone | for pesticide residue & PCB analysis(x300) | 1L |
| 12-4B | Acetone | for pesticide residue & PCB analysis(x300) | 3L |
| 01033-2B | Acetonitrile | for pesticide residue & PCB analysis(x5,000) | 1L |
| 01033-3B | Acetonitrile | for pesticide residue & PCB analysis(x5,000) | 3L |
| 17-2B | Acetonitrile | for pesticide residue & PCB analysis(x300) | 1L |
| 17-3B | Acetonitrile | for pesticide residue & PCB analysis(x300) | 3L |
| 04084-2B | Benzene | for pesticide residue & PCB analysis(x5,000) | 1L |
| 1792-2B | Benzene | for pesticide residue & PCB analysis(x300) | 1L |
| 04418-4B | tert-Butyl methyl ether | for pesticide residue & PCB analysis(x5,000) | 1L |
| 04418-5B | tert-Butyl methyl ether | for pesticide residue & PCB analysis(x300) | 1L |
| 07277-1B | Chloroform | for pesticide residue & PCB analysis(x5,000) | 1L |
| 07278-5B | Chloroform | for pesticide residue & PCB analysis(x300) | 1L |
| 07547-7B | Cyclohexane | for pesticide residue & PCB analysis(x5,000) | 1L |
| 07547-3B | Cyclohexane | for pesticide residue & PCB analysis(x300) | 1L |
| 07547-5B | Cyclohexane | for pesticide residue & PCB analysis(x300) | 3L |
| 10158-3B | Dichloromethane | for pesticide residue & PCB analysis(x5,000) | 1L |
| 10158-4B | Dichloromethane | for pesticide residue & PCB analysis(x5,000) | 3L |
| 6054-3B | Dichloromethane | for pesticide residue & PCB analysis(x300) | 1L |
| 6054-4B | Dichloromethane | for pesticide residue & PCB analysis(x300) | 3L |
| 14134-6B | Diethyl ether | for pesticide residue & PCB analysis(x5,000) | 1L |
| 14134-2B | Diethyl ether | for pesticide residue & PCB analysis(x300) | 1L |
| 14032-1B | Ethanol (99.5) | for pesticide residue & PCB analysis(x5,000) | 1L |
| 14033-4B | Ethanol (99.5) | for pesticide residue & PCB analysis(x300) | 1L |
| 14033-5B | Ethanol (99.5) | for pesticide residue & PCB analysis(x300) | 3L |
| 10972-4B | Ethyl acetate | for pesticide residue & PCB analysis(x5,000) | 1L |
| 10972-5B | Ethyl acetate | for pesticide residue & PCB analysis(x5,000) | 3L |
| 10972-2B | Ethyl acetate | for pesticide residue & PCB analysis(x300) | 1L |
| 10972-3B | Ethyl acetate | for pesticide residue & PCB analysis(x300) | 3L |
| 18041-3B | Hexane | for pesticide residue & PCB analysis(x5,000) | 1L |
| 18041-4B | Hexane | for pesticide residue & PCB analysis(x5,000) | 3L |
| 4371-3B | Hexane | for pesticide residue & PCB analysis(x300) | 1L |
| 4371-4B | Hexane | for pesticide residue & PCB analysis(x300) | 3L |
| 25183-4B | Methanol | for pesticide residue & PCB analysis(x5,000) | 1L |
| 25183-5B | Methanol | for pesticide residue & PCB analysis(x5,000) | 3L |
| 6011-2B | Methanol | for pesticide residue & PCB analysis(x300) | 1L |
| 6011-4B | Methanol | for pesticide residue & PCB analysis(x300) | 3L |
| 32065-1B | Petroleum ether | for pesticide residue & PCB analysis(x5,000) | 1L |
| 1772-2B | Petroleum ether | for pesticide residue & PCB analysis(x300) | 1L |
| 32435-3B | 2-Propanol | for pesticide residue & PCB analysis(x5,000) | 1L |
| 40181-1B | Toluene | for pesticide residue & PCB analysis(x5,000) | 1L |
| 40181-2B | Toluene | for pesticide residue & PCB analysis(x5,000) | 3L |
| 40180-3B | Toluene | for pesticide residue & PCB analysis(x300) | 1L |
| 40180-5B | Toluene | for pesticide residue & PCB analysis(x300) | 3L |
Reagents for PCB & Residual Pesticides Analysis
We provide stable, high-quality products that meet the strict requirements of GC/MS and PCB conformity testing.
PRODUCT LIST
| PRODUCT CODE | ITEM | GRADE | PACKAGE |
|---|---|---|---|
| 01031-79 | Acetonitrile | for thiram analysis | 1L |
| 01031-76 | Acetonitrile | for thiram analysis | 3L |
| 11307-5B | Distilled water, washed with hexane | for pesticide residue analysis | 1L |
| 11307-6B | Distilled water, washed with hexane | for pesticide residue analysis | 3L |
| 37144-1B | Sodium chloride | for pesticide residue & PCB analysis | 500g |
| 6639-1B | Sodium sulfate | for pesticide residue & PCB analysis | 500g |
In pharmaceutical testing, residual solvent analysis is essential to ensure that organic solvents used during manufacturing are within acceptable limits. This analysis is typically performed using gas chromatography (GC) to detect and quantify any remaining solvents in the final product.
Our residual solvent analysis reagents are specifically formulated to support this process by minimizing low-boiling-point impurities such as methanol. Each reagent is quality-assured for suitability in residual solvent testing, ensuring precise, reliable results and compliance with regulatory standards.
PRODUCT LIST
| PRODUCT CODE | ITEM | GRADE | PACKAGE |
|---|---|---|---|
| 10344-07 | N,N-Dimethylformamide | for residual solvent analysis | 500mL |
| 10344-79 | N,N-Dimethylformamide | for residual solvent analysis | 1L |
| 10344-23 | N,N-Dimethylformamide | for residual solvent analysis | 100mL |
| 11208-07 | 1,3-Dimethyl-2-imidazolidinone | for residual solvent analysis | 500g |
| 25336-02 | N-Methyl-2-pyrrolidinone | for residual solvent analysis | 500mL |
| 25336-67 | N-Methyl-2-pyrrolidinone | for residual solvent analysis | 1L |
| 25336-24 | N-Methyl-2-pyrrolidinone | for residual solvent analysis | 100mL |
| PRODUCT CODE | ITEM | GRADE | PACKAGE |
|---|---|---|---|
| 14284-96 | Ethanol standard stock soluton | for gas chromatography | 5mL×5 |
| 18614-96 | Hydrogen chloride-1-butanol solution (10) | for gas chromatography | 1mL×5 |
| 18615-08 | Hydrogen chloride-methanol solution (10) | for gas chromatography | 500mL |
| 18615-33 | Hydrogen chloride-methanol solution (10) | for gas chromatography | 25 mL |
| 18616-96 | Hydrogen chloride-methanol solution (5) | for gas chromatography | 1mL×5 |
| 40047-96 | N-(Trimethylsilyl)imidazole | for gas chromatography | 1mL×5 |
| 04650-96 | N,O-Bis(trimethylsilyl)acetamide (N,O=N,N) | for gas chromatography | 1mL×5 |
| 04906-96 | Boron trifluoride methanol complex, methanol solution | for gas chromatography | 2mL×5 |
| 04651-96 | Bis(trimethylsilyl)trifluoroacetamide | for gas chromatography | 1mL×5 |
| 40048-96 | N-Methyl-N-(trimethylsilyl)trifluoroacetamide | for gas chromatography | 1mL×5 |
